Microlife Microlife
  • Продукция
    • Katalog RU - Icon Каталог
    • BP B3 Comfort_front Термометры
    • MT 850_green Термометры
    • BreastPump_BC200-front Молокоотсосы
    • Gluco-A_front Глюкометры
    • NEB_400_front Ингаляторы, пульсоксиметры, пикфлоуметры
    • Software_downloads_allg Поддержка
  • Тонометры WatchBP
    • WatchBP Office ABI_front_cuff WatchBP Office
    • Website_Header ESC2019_1960x650px WatchBP O3
    • WatchBP Home A_front_cuff WatchBP Home
    • Cuff-Ankle Манжеты и принадлежности
    • Software Software
  • Валидации и клинические исследования
  • Технологии
  • Журнал
  • Поддержка
    • icon_eco Забота об окружающей среде
    • icon_service Сервис
    • BP A2 Basic startseite Поддержка по изделиям
    • Software_downloads_allg Загрузка программного обеспечения
    • Software_downloads_WBP Профессиональное программное обеспечение
    • Software Developers Разработчикам ПО
  • Компания
    • aboutus О нас
    • contact Контакты
    • History История
О’ZBEKISTON
Русский
Europe
  • EUROPE - English
  • CZECHIA - Čeština
  • DANMARK - Dansk
  • DEUTSCHLAND - Deutsch
  • ESPAÑA - Español
  • FRANCE - Français
  • HRVATSKA - Hrvatski
  • ITALIA - Italiano
  • LATVIJA - Latviešu
  • LIETUVA - Lietuvių
  • MAGYARORSZÁG - Magyar
  • NEDERLAND - Nederlands
  • ÖSTERREICH - Deutsch
  • POLSKA - Polski
  • PORTUGAL - Português
  • SCHWEIZ - Deutsch
  • SLOVENSKO - Slovenčina
  • SLOVENIJA - Slovenščina
  • SUOMI - Suomi
  • SCHWEIZ - Français
  • UK - English
  • ΕΛΛΆΔΑ - Ελληνικά
  • БЪЛГАРИЯ - Български
  • СРБИЈА - Српски
  • УКРАЇНА - Українська
  • TÜRKIYE - Türkçe
  • РОССИЯ - Русский
  • БЕЛАРУСЬ - Русский
  • О’ZBEKISTON - Русский
  • О’ZBEKOSTION - O’zbekcha
  • ҚАЗАҚСТАН - Қазақ
  • ҚАЗАҚСТАН - Русский
Asia
  • ASIA PACIFIC - English
  • VIỆT NAM - Tiếng Việt
  • ประเทศไทย - ไทย
  • 中国 - 中文
  • 台灣 - 中文
Middle East and North Africa
  • MENA - Arabic عربى
USA, Latin America
  • US - English
  • AMÉRICA DEL SUR - Español
  • COLOMBIA - Español
  • MÉXICO - Español
Menu
Headerpictures WatchBP Validations AFIB Flow

Screening for atrial fibrillation with automated blood pressure measurement: Research evidence and practice recommendations

Home > Тонометры WatchBP > Валидации и клинические исследования > Screening for atrial fibrillation with automated blood pressure measurement: Research evidence and practice recommendations, Verberk, 2016
Share

Willem J. Verberk, Stefano Omboni, Anastasios Kollias, George S. Stergiou, 2016

Clinical Study of Microlife WatchBP AFIB

Abstract

Several guidelines recommend opportunistic screening for atrial fibrillation (AF) in subjects aged ≥65 years using pulse palpation during routine blood pressure (BP) measurement. However, this method has limited diagnostic accuracy. A specific algorithm for AF detection during automated BP measurement was developed and implemented in a novel oscillometric device (MicrolifeWatchBP Home-A). In 2013, the UK National Institute for Health and Care Excellence (NICE) recommended this device for AF screening during routine office BP measurement in primary care in subjects ≥65 years. A review and meta-analysis of the evidence on the diagnostic accuracy of this algorithm were performed. Six studies (n=2332) investigated the accuracy of AF detection using the Microlife BP monitor and estimated a pooled sensitivity at 0.98 (95% CI 0.95, 1.00) and specificity 0.92 (0.88, 0.96). Analysis of 4 studies (n= 1126) showed more readings to improve specificity (from 0.86 to 0.91) and sensitivity (from 0.97 to 0.99). Taking 3 sequential readings with at least 2 detecting AF gave the highest diagnostic accuracy. A single study (n=139) of paroxysmal AF screening with home BP monitoring (3316 days) showed sensitivity 99% and specificity 93%. Another study (n = 46) of AF screening with 24 h ambulatory BP monitoring showed that AF detected in N15% of all readings has high probability of AF diagnosis requiring confirmation by 24 h electrocardiography. AF detection with routine automated BP measurement is a reliable screening tool in the elderly, which requires confirmation by electrocardiography. Paroxysmal AF might also be detected by routine automated home or ambulatory BP monitoring.

Click here to download the abstract in pdf format.

Click here to view the clinical study on pubmed.gov.

WatchBP Office ABI_front_cuff

WatchBP Office

Посмотреть изделия
WatchBP Home A_half_cuff

WatchBP Home A

Посмотреть изделие
BP-A7-Touch-BT_half_soft-cuff_with_button

BP A7 Touch BT

Посмотреть изделие
Microlife
  • Контакты по Узбекистану и СНГ
  • Поддержка
  • Выходные данные
  • Политика конфиденциальности
  • Условия использования
Логин
Copyright © 2025 - Microlife Corporation. All rights reserved.