Microlife Microlife
  • Продукция
    • Katalog RU - Icon Каталог
    • BP B3 Comfort_front Термометры
    • MT 850_green Термометры
    • BreastPump_BC200-front Молокоотсосы
    • Gluco-A_front Глюкометры
    • NEB_400_front Ингаляторы, пульсоксиметры, пикфлоуметры
    • Software_downloads_allg Поддержка
  • Тонометры WatchBP
    • WatchBP Office ABI_front_cuff WatchBP Office
    • Website_Header ESC2019_1960x650px WatchBP O3
    • WatchBP Home A_front_cuff WatchBP Home
    • Cuff-Ankle Манжеты и принадлежности
    • Software Software
  • Валидации и клинические исследования
  • Технологии
  • Журнал
  • Поддержка
    • icon_eco Забота об окружающей среде
    • icon_service Сервис
    • BP A2 Basic startseite Поддержка по изделиям
    • Software_downloads_allg Загрузка программного обеспечения
    • Software_downloads_WBP Профессиональное программное обеспечение
    • Software Developers Разработчикам ПО
  • Компания
    • aboutus О нас
    • contact Контакты
    • History История
О’ZBEKISTON
Русский
Europe
  • EUROPE - English
  • CZECHIA - Čeština
  • DANMARK - Dansk
  • DEUTSCHLAND - Deutsch
  • ESPAÑA - Español
  • FRANCE - Français
  • HRVATSKA - Hrvatski
  • ITALIA - Italiano
  • LATVIJA - Latviešu
  • LIETUVA - Lietuvių
  • MAGYARORSZÁG - Magyar
  • NEDERLAND - Nederlands
  • ÖSTERREICH - Deutsch
  • POLSKA - Polski
  • PORTUGAL - Português
  • SCHWEIZ - Deutsch
  • SLOVENSKO - Slovenčina
  • SLOVENIJA - Slovenščina
  • SUOMI - Suomi
  • SCHWEIZ - Français
  • UK - English
  • ΕΛΛΆΔΑ - Ελληνικά
  • БЪЛГАРИЯ - Български
  • СРБИЈА - Српски
  • УКРАЇНА - Українська
  • TÜRKIYE - Türkçe
  • РОССИЯ - Русский
  • БЕЛАРУСЬ - Русский
  • О’ZBEKISTON - Русский
  • О’ZBEKOSTION - O’zbekcha
  • ҚАЗАҚСТАН - Қазақ
  • ҚАЗАҚСТАН - Русский
Asia
  • ASIA PACIFIC - English
  • VIỆT NAM - Tiếng Việt
  • ประเทศไทย - ไทย
  • 中国 - 中文
  • 台灣 - 中文
Middle East and North Africa
  • MENA - Arabic عربى
USA, Latin America
  • US - English
  • AMÉRICA DEL SUR - Español
  • COLOMBIA - Español
  • MÉXICO - Español
Menu
Header Microlife & WatchBP Clinical Studies Flow

Rapid Assessment of Blood Pressure in the Obstetric Day Unit Using Microlife MAM Technology

Home > Тонометры WatchBP > Валидации и клинические исследования > Rapid Assessment of Blood Pressure in the Obstetric Day Unit Using Microlife MAM Technology, Wilton A, 2006
Share

Anja Wilton, Annemarie De Greef, and Andrew Shennan, 2006

Abstract

Rapid Assessment of Blood Pressure in the Obstetric Day Unit Using Microlife MaM Technology

Maternal and Fetal Health Research Unit, Division of Reproduction and Endocrinology, King’s College London School of Medicine at Guy’s, King’s College and St. Thomas’ Hospital, London, UK

Objective
To compare MAM technology with current methods of assessing blood pressure (BP) over time on the obstetric day unit. Background: It is recommended that the average of repeated measures is used to confirm hypertension in pregnancy. The Microlife 3AC1 is a validated oscillometric device featuring “MAM” mode using the average of at least 3 BP readings 15 seconds apart. This allows rapid assessment of BP. The difference between each measurement is calculated and influences the percentage contribution to the final average reading. We compared MaM with readings taken in a conventional manner.


Methods
Blood pressure was measured in 30 hypertensive pregnant patients recruited from the obstetric day unit of a large teaching hospital. Single BP measurements were taken at 0, 15, 30, 60, and 90 minutes using the Microlife BP 3BT0-A[2]. Simultaneous measurements (in the opposite arm) were also taken at 0 and 90 minutes using MAM technology.

Results​
Systolic BP fell over 90 minutes (p = 0.035) compared with the first single reading, but diastolic BP did not (p = 0.54). The difference between the first MAM and the first single reading was significantly different for systolic BP (5.6 mm Hg, p = 0.017), but not for diastolic (0.6 mm Hg, p = 0.39). The mean of all single readings and the first MAM reading were similar for both systolic and diastolic BP (SBP: 0.3 mm Hg, p = 0.75, DBP: 0.2 mm Hg, p = 0.87).

Conclusion
White-coat hypertension exists for systolic BP in the obstetric day unit. The MAM technology allows rapid and accurate characterization of blood pressure equivalent to repeated measures over 90 minutes.

Click here to download the abstract in pdf format